Chungmei CM-P3-01L Fire Alarm Control Panel
Product Feature
- Comprehensive circuit monitoring and corresponding indicators: each circuit is equipped with monitoring functions on fire, circuit break and short circuit, respectively
- The fire alarm circuit and the indicator circuit are able to detect circuit break and offer protection against short circuit
- The system always keeps close watch over battery charging and the voltage of the stand-by battery to ensure that the central control unit functions well in all circumstances to prevent any disaster
- Each circuit is equipped with a testing button to ensure the normal function of each monitoring circuit
- Key-controlled function switchesΒ prevent false alarms caused by accidental touch
- Digital detection of voltage error: whenever a voltage error is detected by the system, an error alarm will sound and an indicator will light on
- The system is equipped with aΒ two-stage accumulation functionΒ to prevent false alarms. When the detector activates for the first time, the system will automatically reset the detector. If another signal is received later, the system will then confirm that there is a fire, for fear of a false alarm
- βSelf-Protectionβ mode and βNon Self-Protectionβ modeΒ are available to fire alarms
- Separate control switches: separate control panels for main audio, local audio, indicators, and reporting output
- There is a βNot-Locatedβ indicator above each switch
- Digital-electronic switches are used due to advantages of dust proofing and a long service life
- A control panel with all necessary master indicators: the status of system alarm, power supply quality, and circuit connection are shown
- The alarm buzzer sounds in a loud voice: personnel in charge will be informed immediately in case of a firm alarm
- A large fire indicator: in case of a fire, a fire alarm will sound and the large fire indicator will flash
SPECIFICATION
MODEL NO. | CM-P3 |
---|---|
POWER SUPPLY | 240V AC 50/60 HzΒ Β± 10% |
STANDBY BATTERY | 24V DC / Lead-Acid (Non-Spillable) Battery |
E.O.L RESISTOR | 10 KΞ© |
EXTERNAL CIRCUIT | To-and -fro below 50Β Ξ© |
NO. OF BELLS | 1 time of panel circuits |
CHARGING VOLTAGE & CIRCUIT | 26V DC below 450mA, Trickle Charging |
CURRENT VOLTAGE | 24V DC operation voltage, below 5V 32mA |
CHARGING CURRENT | 26.4V DC, under 450mA, Trickle Charge |
DETECTORS | No limit of R.O.R or Fixed Temp. Heat Detector can be installed; Each circuit can connect to a maximum of 20 smoke detectors (standby current for detector: 24V DC 25 ΞΌA below). |
NO. OF INDICATORS | 1 time of panels circuits |
CASE MATERIAL | Standard Material of 1.2mm |
REPORT CONTACT | No voltage N.O. contact Capacity 250V AC 7A Γ 2 sets |
ORDER INFORMATION
CM-P3-1L | FACP 01 zone with battery |
---|---|
CM-P3-2L | FACP 02 zone with battery |
CM-P3-4L | FACP 04 zone with battery |
CM-P3-8L | FACP 08 zone with battery |
CM-P3-12L | FACP 12 zone with battery |
CM-P3-16L | FACP 16 zone with battery |
CM-P3-24L | FACP 24 zone with battery |
EXTERNAL DIMENSIONS
MODEL | WALL MOUNTING TYPE | ||
---|---|---|---|
CIRCUIT NO. | 1L/2L/4L/8L | 12L/16L | 24L |
H (MM) | 400 | 495 | 580 |
W (MM) | 300 | 300 | 300 |
D (MM) | 120 | 120 | 120 |