Chungmei CM-P3-16L Fire Alarm Control Panel | A250

$299.00

  • Advantages
  • Fire Alarm Control Panel
  • 16 ZONES
  • Key-controlled function switches prevent false alarms caused by accidental touch.
  • The fire alarm circuit and indicator circuit are able to detect circuit break and offer protection against short circuit.
Categories: ,

Description

Chungmei CM-P3-16L Fire Alarm Control Panel

Product Feature

  • Comprehensive circuit monitoring and corresponding indicators: each circuit is equipped with monitoring functions on fire, circuit break and short circuit, respectively
  • The fire alarm circuit and the indicator circuit are able to detect circuit break and offer protection against short circuit
  • The system always keeps close watch over battery charging and the voltage of the stand-by battery to ensure that the central control unit functions well in all circumstances to prevent any disaster
  • Each circuit is equipped with a testing button to ensure the normal function of each monitoring circuit
  • Key-controlled function switchesย prevent false alarms caused by accidental touch
  • Digital detection of voltage error: whenever a voltage error is detected by the system, an error alarm will sound and an indicator will light on
  • The system is equipped with aย two-stage accumulation functionย to prevent false alarms. When the detector activates for the first time, the system will automatically reset the detector. If another signal is received later, the system will then confirm that there is a fire, for fear of a false alarm
  • โ€œSelf-Protectionโ€ mode and โ€œNon Self-Protectionโ€ modeย are available to fire alarms
  • Separate control switches: separate control panels for main audio, local audio, indicators, and reporting output
  • There is a โ€œNot-Locatedโ€ indicator above each switch
  • Digital-electronic switches are used due to advantages of dust proofing and a long service life
  • A control panel with all necessary master indicators: the status of system alarm, power supply quality, and circuit connection are shown
  • The alarm buzzer sounds in a loud voice: personnel in charge will be informed immediately in case of a firm alarm
  • A large fire indicator: in case of a fire, a fire alarm will sound and the large fire indicator will flash

SPECIFICATION

MODEL NO. CM-P3
POWER SUPPLY 240V AC 50/60 Hzย ยฑ 10%
STANDBY BATTERY 24V DC / Lead-Acid (Non-Spillable) Battery
E.O.L RESISTOR 10 Kฮฉ
EXTERNAL CIRCUIT To-and -fro below 50ย ฮฉ
NO. OF BELLS 1 time of panel circuits
CHARGING VOLTAGE & CIRCUIT 26V DC below 450mA, Trickle Charging
CURRENT VOLTAGE 24V DC operation voltage, below 5V 32mA
CHARGING CURRENT 26.4V DC, under 450mA, Trickle Charge
DETECTORS No limit of R.O.R or Fixed Temp. Heat Detector can be installed; Each circuit can connect to a maximum of 20 smoke detectors (standby current for detector: 24V DC 25 ฮผA below).
NO. OF INDICATORS 1 time of panels circuits
CASE MATERIAL Standard Material of 1.2mm
REPORT CONTACT No voltage N.O. contact
Capacity 250V AC 7A ร— 2 sets

ORDER INFORMATION

CM-P3-1L FACP 01 zone with battery
CM-P3-2L FACP 02 zone with battery
CM-P3-4L FACP 04 zone with battery
CM-P3-8L FACP 08 zone with battery
CM-P3-12L FACP 12 zone with battery
CM-P3-16L FACP 16 zone with battery
CM-P3-24L FACP 24 zone with battery

EXTERNAL DIMENSIONS

MODEL WALL MOUNTING TYPE
CIRCUIT NO. 1L/2L/4L/8L 12L/16L 24L
H (MM) 400 495 580
W (MM) 300 300 300
D (MM) 120 120 120

Reviews

There are no reviews yet.

Be the first to review “Chungmei CM-P3-16L Fire Alarm Control Panel | A250”

Your email address will not be published. Required fields are marked *